Home/Knowledge/Quality/How to test a pack's true capacity
Knowledge / Quality

How to test a pack's true capacity

A practical method for verifying advertised Ah and Wh, including the test conditions that change the result.

Quality7 min readUpdated Nov 2026

“5.0Ah” is a claim, not a measurement. Testing it properly takes a discharge rig, a consistent load and a defined cut-off voltage.

The basic method

  • Charge the pack to full with a charger that terminates correctly.
  • Rest for 30 minutes at room temperature.
  • Discharge at a constant current — typically 0.2C, so 1A for a 5.0Ah pack — to the cut-off voltage.
  • Multiply current by time to get Ah; multiply by average voltage for Wh.

Why results vary

Capacity depends on temperature, discharge rate and cut-off. A pack tested at 10°C or at 3C will read lower than one tested at 25°C and 0.2C. Always compare under the same conditions.

What counts as passing

A common commercial threshold is 95% of nominal: a 5.0Ah pack should test at 4.75Ah or better. Below that, the pack is under-spec and should be rejected rather than downgraded and sold.

A field check buyers can run

Run a known tool under a fixed load and time it against a known-good pack. It is less precise than a discharge rig, but it catches gross overstatement quickly.

Put the test method in the purchase contract. A capacity clause with a defined load, temperature and cut-off is enforceable; “good quality” is not.