“5.0Ah” is a claim, not a measurement. Testing it properly takes a discharge rig, a consistent load and a defined cut-off voltage.
The basic method
- Charge the pack to full with a charger that terminates correctly.
- Rest for 30 minutes at room temperature.
- Discharge at a constant current — typically 0.2C, so 1A for a 5.0Ah pack — to the cut-off voltage.
- Multiply current by time to get Ah; multiply by average voltage for Wh.
Why results vary
Capacity depends on temperature, discharge rate and cut-off. A pack tested at 10°C or at 3C will read lower than one tested at 25°C and 0.2C. Always compare under the same conditions.
What counts as passing
A common commercial threshold is 95% of nominal: a 5.0Ah pack should test at 4.75Ah or better. Below that, the pack is under-spec and should be rejected rather than downgraded and sold.
A field check buyers can run
Run a known tool under a fixed load and time it against a known-good pack. It is less precise than a discharge rig, but it catches gross overstatement quickly.
Put the test method in the purchase contract. A capacity clause with a defined load, temperature and cut-off is enforceable; “good quality” is not.